Categories onse

Kunyumba> Zamgululi > Backup Power Management > Mphamvu zosunga zobwezeretsera

Mphamvu zosunga zobwezeretsera
  • SAT-RSL
  • SAT-RSL

SAT-RSL FDC mndandanda wa Rack-wokwera wotengera katundu

  • Description:
  • 1). Meet the most commonly used power supply

    2). Compact structure

    3). Support constant current

    4). With overvoltage/overcurrent/overheating protection functions;

    5). Kulondola kwambiri kwa mayeso

    6). Thandizani kusintha


  • Lumikizanani Tsopano
  • SAT-RSL
  • SAT-RSL

Tel: + 86 88115682

E-mail: sales@aitelong.com

  • Kufotokozera

The FDC series rack-mounted simulated load uses the latest discharge power modulation technology. As the end load, it can detect the load capacity of the AC/DC system and the performance of the backup battery pack. The device can fully simulate the power usage, heat dissipation and other air flow changes of the server. It is widely used in the output power, heat dissipation and load capacity testing of the power distribution system of data centers and operator IDC computer rooms.

 

Features Ofunika

l Meet the test of the most commonly used power supply systems in IDC computer rooms, such as AC220V, DC240V, DC336V, DC110V, and DC48V;

l Compact structure, standard 19-inch 3U/4U design, can achieve a maximum test power of 10KW;

l Support constant current, constant resistance, and constant power test modes, can simulate the actual load of the computer room after the mains power is interrupted, so as to conduct a comprehensive test and evaluation of the power supply capacity of the backup battery;

l With overvoltage, overcurrent, and overheating automatic protection functions;

l Automatically cut off the discharge power part in case of abnormal conditions to ensure equipment safety;

l Adopting the latest high-efficiency alloy materials, the load does not generate red heat during the test, which complies with UL safety regulations;

l High test accuracy, power accuracy deviation <2%, can accurately reflect the load capacity of the tested equipment;

l Optional segmented digital voltage, current meter, LCD power meter;

l Manual control, multi-device parallel operation, remote control (optional)

l Support customization to meet the needs of higher power testing.


mfundo

lachitsanzo

Mitundu yamagalimoto

mphamvu

kukula

FDC220V/240V-6KW

Chithunzi cha DC180V-DC300V

(Constant current, constant resistance, constant power)

O-6KW

450 * 134 * 480mm

48V-9KW

Chithunzi cha DC24V-DC60V

(Constant current, constant resistance, constant power)

0-9KW

450 * 134 * 480mm

110V-7KW

Chithunzi cha DC80V-DC150V

(Constant current, constant resistance, constant power)

0-7KW

450 * 134 * 480mm

336V-5KW

Chithunzi cha DC220V-DC400V

(Constant current, constant resistance, constant power)

0-5KW

450 * 134 * 480mm

Function and power can be customized according to user needs

 


Fomu Contact

Magulu otentha